Permit-Ready Cleanroom Addition Drawings
$250-750 USD
Posted 1 minute ago
•
Ends in 23 hours
$250-750 USD
Paid on delivery
Seeking a qualified Architect, Engineer, or Commercial CAD Designer to produce permit-ready construction drawings for a 10' W × 15' L × 10' H (150 sq. ft.) cleanroom gowning room addition inside our 219,900 sq. ft. medical kitting facility in High Point, NC. Scope of Drawings Needed: • Architectural & Structural Layout: Floor plan, framing details, and elevations for a non-load-bearing steel stud enclosure anchored to the existing concrete slab (specifying Hilti powder/gas-actuated track fastening systems per Section 3.2.6). • Cleanroom Finishes & Openings: Wallboard/ceiling assemblies, seamless commercial vinyl flooring, integration of two existing doors, one new entry door, and one cleanroom passthrough unit. • Electrical & Lighting Plan: Reflected ceiling plan and circuit layout for three 120V duplex outlets and ISO 5–9 rated 2' × 4' LED flat panel fixtures (show layouts/options for both 12 fixtures and 9 fixtures). (Note: HEPA Fan Filter Units are excluded). • Mechanical/HVAC Detail: Show disconnect, relocation, and reconnection of an existing air curtain at the new entry configuration. • Code Compliance & Permitting: Ensure full compliance with North Carolina State Building Codes, NEC, and egress requirements for City of High Point municipal permit submittal.
Project ID: 40816973
About the project
5 proposals
Open for bidding
Remote project
Active 10 secs ago
Place your bid
Bid amount Email addressBenefits of bidding on Freelancer
Set your budget and timeframe
It's free to sign up and bid on jobs
5 freelancers are bidding on average $438 USD for this job


Hello, I will draft comprehensive permit-ready construction drawings for the cleanroom gowning room addition, adhering to North Carolina State Building Codes and ANSI standards. I will provide detailed architectural layouts, electrical plans, and mechanical HVAC details that ensure compliance and functionality. Just a couple of technical questions: 1. What specific cleanroom class and airflow requirements are to be considered for the design, particularly regarding the HEPA filtration system? 2. Are there any existing structural constraints or environmental factors at the site that I should account for when designing the foundation and anchoring systems? Looking forward to collaborating on this. Portfolio: https://www.freelancer.com/u/anthonym873


Hi there, we might be new to the platform but I'd love to share some relevant examples. Your project, producing permit-ready construction drawings for a cleanroom gowning room addition, sounds right up our alley and we would love to exceed your expectations. We understand the necessity for a polished architectural and structural layout for your non-load-bearing steel stud enclosure and the importance of seamless integration with your existing facility. Our team excels in creating user-friendly designs while ensuring compliance with local codes and regulations. While we might be new to Freelancer, we have over 9 years of experience off-site, and we have multiple 5-star reviews on similar projects. We rank in the top 1 percent among 75 million users. I truly appreciate you taking your time to review our proposal and I would love to discuss this project more. Kind regards, Trichelle Client name is Trich123.


My 9 years of U.S. experience delivering coordinated architectural, structural, and MEP construction documents directly match this cleanroom addition and its permit-submittal requirements. I design commercial additions, tenant improvements, renovations, and existing-building modifications, including non-load-bearing steel framing, concrete slab connections, openings, and detailed construction documentation. I can develop the floor plan, elevations, framing and enclosure details, cleanroom finishes, door and passthrough coordination, reflected ceiling and electrical layouts, and the air-curtain relocation detail. My background in AutoCAD, building architecture, structural design, mechanical engineering, and multidisciplinary coordination supports a complete drawing set aligned with North Carolina building-code, NEC, and egress considerations for High Point permitting. I focus on accurate, practical, well-organized permit-ready documents and would be pleased to deliver the coordinated drawing package for your medical kitting facility.
内容来自 Freelancer News,版权归原作者所有。
阅读原文 ↗