I need a clean, professional one-line diagram drawn in AutoCAD for a grid-tied solar PV system that includes battery backup. The drawing must be ready for submittal to my authority having jurisdiction as well as the utility interconnection review, so it must reflect current NEC conventions and typical utility requirements for distributed generation. I will supply the site information and all available equipment specifications—panels, inverter, batteries, combiner, disconnects, breakers, meter location—once we start. You may have to fill in standard symbols, conductor sizes, and protection devices to round out the document, but everything will be verified with me before finalization. Accuracy and neat layering are important because the utility will scrutinize the file. Deliverables: 1. Native AutoCAD (.dwg) file with organized layers and editable blocks 2. A flattened PDF stamped “For Review” Please include a brief note on how you normally show PV point of interconnection, battery ESS isolators, and rapid-shutdown devices so I know we are on the same page.
Project ID: 40837923
About the project
14 proposals
Remote project
Active 6 mins ago
Looking to make some money?
Email addressBenefits of bidding on Freelancer
Set your budget and timeframe
It's free to sign up and bid on jobs
14 freelancers are bidding on average $161 USD for this job


My 12 years of professional experience producing permit and submission drawing packages makes me well suited to prepare a clean, review-ready AutoCAD one-line diagram for your solar PV and battery system. I specialise in accurate construction documentation and editable CAD drawings, with strong attention to detail, organised drafting and professional presentation.


Dear Sir, Please contact me to get started. Thanks. I am an Electrical Design Engineer having 15+ years of experience in Design of Electrical System for Residential and Commercial low/high rise buildings. I will provide all aspects of Electrical System for your project as per standards (NEC or any local if any) and specification within the required time and budget. I will also share my previous samples. Well versed in; 1. Lighting Layouts 2. Power Layouts 3. Single Line Diagram 4. Fire Alarm System 5. ELV (Subject to Client’s requirement) 6. Lighting Protection System 7. Design Calculations 8. Equipment Installation Detail Drawings. 9. Take-off sheets and Bills of quantity 10. Technical Specifications and more.


Your grid-tied solar PV + battery backup single-line diagram (SLD), drafted in cleanly layered AutoCAD and fully aligned with current NEC (Articles 690 & 705) and utility interconnection standards within 24 hours. I'll integrate all your site equipment specs, verify conductor sizing, OCPD ratings, and equipment grounding paths, and deliver an AHJ- and utility-ready package. The critical challenge is clearly depicting NEC 690.12 rapid shutdown initiation/boundaries, NEC 706 ESS disconnecting means, and NEC 705.12 point-of-interconnection (POI) busbar compliance so utility reviewers pass the submittal without redlines. I normally show rapid shutdown via dashed control boundaries with an explicit initiator callout at the AC disconnect/service, dedicated lockable visible-blade AC/DC ESS isolators with clear normal-open/closed states, and a detailed POI callout noting main breaker, busbar rating, and backfeed breaker compliance (120% rule or supply-side tap). Deliverables: Cleanly structured native AutoCAD (.dwg) file with standardized IEEE/NEC blocks, organized layer hierarchy, full conductor/conduit/breaker schedules, and a flattened PDF set stamped "For Review". Could you share your site equipment specs (inverter, battery ESS, PV module/string count, and main service panel rating) along with your preferred point-of-interconnection method (load-side backfeed vs. supply-side tap)? Thank you. Kind regards,


Gridline Digital Studio specialises in accurate, construction-ready AutoCAD and electrical/MEP documentation, making this a strong match for a utility- and AHJ-ready solar PV one-line diagram. I can deliver the native DWG with organised layers and editable blocks, together with the flattened “For Review” PDF you require.


Hello, The most important aspect of this project is producing an accurate, professionally organized single-line diagram that clearly communicates the PV system, battery energy storage, protection devices, and utility interconnection. I'd develop the drawing in AutoCAD using organized layers, reusable electrical symbols, and clearly identified equipment connections. My technical approach: • PV System: Show solar panel strings, DC combiner, inverter inputs, disconnects, and associated overcurrent protection. • Point of Interconnection (POI): Clearly identify the utility meter, service panel, main breaker, and PV backfeed connection, including applicable busbar and breaker ratings. • Battery ESS: Illustrate battery connections, dedicated isolation devices, overcurrent protection, and inverter integration. • Rapid Shutdown: Identify the required rapid-shutdown equipment, initiation device, and controlled PV conductors. • Electrical Protection: Document conductor sizes, grounding, bonding, disconnects, and protective devices based on verified equipment ratings and applicable code requirements. Timeline: 3–5 days after receiving the equipment specifications. Fixed price: $180 USD, subject to drawing complexity. Best regards, Zhai Kun


I'll draw your grid-tied PV one-line diagram in AutoCAD with the array strings, inverter, battery ESS, combiner, AC and DC disconnects, rapid-shutdown devices, OCPD and conductor schedule, and the utility point of interconnection, following current NEC conventions once I have your panel, inverter and battery specs and the meter location. You get a native DWG with organised layers and editable blocks plus a flattened PDF marked For Review. I'll send an early draft to verify every device rating and conductor size, and show the POI, ESS isolator and rapid-shutdown devices the way utility reviewers expect. Ready to start right away. Thanks!


I'll draft the grid-tied PV and battery one-line diagram in AutoCAD, showing the PV strings, inverter, battery ESS, combiner, main and backup disconnects, breakers and the utility meter point, with the point of interconnection, ESS isolators and rapid-shutdown devices drawn to NEC conventions. Once I have your panel, inverter and battery data, I'll deliver the native DWG with organised layers and editable blocks, plus a flattened PDF marked For Review, and confirm every symbol, conductor size and protection rating with you before final. The layout will suit both your authority and utility reviewers, and I'll have a first draft ready tomorrow so we can align on conventions early. Thanks!


My electronics and hardware engineering background makes me well suited to produce a clear solar PV electrical diagram that accurately represents equipment, protection, disconnects, and system connections. I work with analog and digital circuit design, schematic capture, circuit development, simulation, and analysis—experience directly relevant to documenting a grid-tied PV system with battery backup. My multidisciplinary engineering experience also includes mechanical engineering projects and professional CAD drafting in SolidWorks, giving me a strong foundation in organized technical drawings, readable layouts, and precise equipment representation. I can create an editable AutoCAD DWG with structured layers and blocks, together with the requested flattened PDF marked “For Review,” while incorporating the supplied panel, inverter, battery, combiner, disconnect, breaker, and meter information.


I show POI per NEC 705.12 (backfed breaker with 120% busbar check or supply-side tap), a lockable 706.15 ESS disconnect, and 690.12 rapid-shutdown MLPE with initiator. You get a layered AutoCAD DWG with editable blocks plus a For Review PDF in 2-3 days. Drop your specs or sketch in chat and I'll start.


My 12+ years delivering permit-ready architectural, structural, MEP, and civil construction documents make me well suited to produce an accurate solar PV one-line diagram for AHJ and utility review. AutoCAD is central to my drafting work, and my Electrical Engineering, MEP coordination, and code-compliant documentation skills support a clean, editable DWG with organized layers and professional presentation. I can develop the grid-tied PV and battery-backup layout from your equipment specifications, incorporating the inverter, ESS, combiner, disconnects, breakers, meter, conductor information, and protection devices into a clear one-line representation. I normally show the PV point of interconnection at the designated service or load-side connection with the associated disconnecting and overcurrent protection, identify battery ESS isolators between the batteries and inverter, and indicate rapid-shutdown equipment and initiation points in a clearly labeled section consistent with the selected system and applicable requirements. The final package can include the native AutoCAD file and a flattened PDF marked “For Review.” I would be glad to prepare a precise, review-ready drawing that can be verified with you before finalization.


Hi, I can draw a clean, submittal-ready AutoCAD one-line for your PV and battery system, built to the NEC edition your AHJ has adopted and your utility's interconnection requirements. How I normally show the key items: - Point of interconnection: clearly labelled as supply-side (705.11) or load-side (705.12). For load-side, I show the busbar 120% rule calculation on the sheet, with the PV/inverter breaker at the opposite end from the main - Battery ESS: its own lockable disconnecting means per 706.15, overcurrent protection on the battery conductors, and the ESS clearly separated from the PV source circuits. Backup loads panel and transfer or microgrid device shown with their isolation points - Rapid shutdown: MLPE devices shown inside the array boundary per 690.12, with the initiator at the service location and the required labels referenced The drawing will also include: - Conductor and conduit callouts, OCPD and disconnect ratings, and grounding and bonding - Utility visible, lockable AC disconnect and production meter if your utility requires them - Equipment schedule, general notes, and a placard and label list (690, 705, 706) - Organised layers (equipment, conductors, text, dimensions, title block) and editable blocks Every assumed value is flagged for your check. Deliverables: native DWG and a flattened PDF stamped "For Review". Time: 2 days after receiving the equipment specs. Best regards,