We are MSTFA Industries, a Houston medical device startup. We have a handheld spirometer (lung function tester) that is designed, assembled and partly debugged, but it has not taken a flow measurement yet. We need an experienced embedded hardware engineer to take it from here to 3 working, bench-tested units and a complete file package we can hand to a board house. Speed matters more than polish: a better v2 comes later, and the right person is likely to get that work too. WHAT EXISTS (full files shared after NDA) - Small double-sided custom board: ESP32-S3, TI TDC1000 ultrasonic front end + TDC7200 time-to-digital converter, two 40 kHz ultrasonic transducers, OLED, Li-ion charging - A pin-by-pin audit found 8 known faults, all in digital control pins or clock choice. The analog receive chain checked correct. TDC1000 SPI communication is verified. - MicroPython firmware drivers for both TI chips, flow math, display and Bluetooth (not yet run end to end) - 3D-printed flow tube and enclosure (CAD available) - A designed backup path using a Sensirion SDP810 differential pressure sensor on the existing I2C port WHAT WE NEED, BY MILESTONE (fixed price per milestone, paid through platform escrow) M1. Review and plan (about 1 week) Review the files, confirm the fault list, and recommend the fastest reliable path: fix the TI ultrasonic path, switch to a dedicated ultrasonic flow chip, or ship v1 on the pressure sensor. Deliver a written plan with a firm price and dates for M2 to M4. M2. Rev B hardware Schematic and PCB with all faults fixed. Add a temperature/humidity/pressure sensor (for example a BME280) for body-temperature correction. Run design-rule and assembly checks for JLCPCB. Deliver Gerbers, BOM with LCSC/DigiKey part numbers, pick-and-place file, and editable source files. We review before ordering, and we pay for fabrication and parts directly. M3. Firmware and bring-up On the Rev B boards: flow (L/s) and volume (L) sampled at 100 Hz or faster; FEV1, FVC, FEV1/FVC and PEF from a forced exhalation; body-temperature correction; a calibration routine; results on the OLED and over Bluetooth or serial. Source code in our Git repo with build instructions. MicroPython or C/C++ is fine, but justify a switch. M4. Integration, testing and hand-off 3 complete working units in the printed tube and enclosure (update the CAD if needed; deliver STEP + STL). A bench report using a 3-liter calibration syringe: at least 3 speeds x 5 strokes, volume error for every stroke, and zero-flow drift over 10 minutes. Raw data included. Hand-off pack: assembly instructions, test procedure, known-issues list, all source files. Accuracy: report the real numbers. Our long-term target is the ATS standard (within 2.5% or 0.050 L), but this phase is about a working, measured prototype, not clinical accuracy. YOU HAVE - Shipped at least one ultrasonic time-of-flight, flow or precision timing product (TDC1000/TDC7200, MSP430FR604x, TDC-GP30 or similar) - Mixed-signal PCB design experience (EasyEDA, KiCad or Altium) - ESP32 firmware experience - An oscilloscope and bench supply, and you can receive hardware by mail (US-based preferred) - Bonus: medical devices, spirometry, or Sensirion pressure sensors TERMS - Budget: up to $5,000 total, fixed price by milestone. Quote each milestone separately. - Target: about 6 to 8 weeks end to end. - NDA and IP assignment signed before any files are shared. All work is work-for-hire and belongs to MSTFA on payment. - All payments go through the platform's escrow, milestone by milestone. No upfront payments and no payments outside the platform. - Weekly 20-minute video check-in. TO APPLY, answer these (start your proposal with the word "spirometer"): 1. Describe one ultrasonic or flow sensing product you built: which chip, and what accuracy you reached. 2. A TDC7200 returns 0xFF on every register. What do you check first? 3. What is the fastest path from today to a first verified volume reading, and how many days would it take you? 4. Your price and timeline for each milestone. 5. What bench equipment do you have?
Project ID: 40837754
About the project
21 proposals
Open for bidding
Remote project
Active 8 secs ago
Place your bid
Bid amount Email addressBenefits of bidding on Freelancer
Set your budget and timeframe
It's free to sign up and bid on jobs
21 freelancers are bidding on average $309 USD for this job


Hello, spirometer Embedded ESP32 firmware, mixed-signal PCB design and bench-tested instrumentation are core capabilities of our US engineering team. Since 2016, Live Experts LLC has completed 423 projects with a 4.9/5 rating, including modular LabVIEW data-acquisition systems and an SMS/GPS relay-control prototype tested on our bench and shipped. Our team works with ESP32, C/C++, Python, BLE, signal processing, KiCad and Eagle PCB design, with full source, schematics and technical documentation hand-off. That aligns well with your Rev B board package, TI-driver integration, calibration workflow, 100 Hz sampling, Bluetooth/serial output and three-unit bench validation. We can also support STEP/CAD processing and structured test reports. For the TDC7200 symptom, I would first verify power, reset, SPI mode and chip-select timing, then confirm the device is actually selected and clocked, inspect logic-analyzer waveforms, and check register addressing against the datasheet before changing firmware. The fastest route to a verified volume reading is to preserve the validated analog chain, correct the known digital faults and exercise the existing TI path first; if it remains blocked, the documented SDP810 backup provides a practical fallback. I can work milestone-by-milestone under escrow and deliver a measured, honest prototype package for MSTFA. Thanks!


Hello, spirometer My strongest fit is the combination of ESP32 embedded development, mixed-signal PCB design, firmware, sensor integration, and prototype testing needed to take your existing board through Rev B and three working units. I work with ESP32, embedded C/C++, driver development, BLE/Wi-Fi, Altium, KiCad and EasyEDA, and can produce schematics, layouts, Gerbers, BOMs and manufacturing documentation. For M1, I would first verify the TDC7200 power, reset, SPI mode and chip-select behavior, register address/read sequencing, clock and START/STOP timing, level compatibility, and whether the device is actually selected before investigating the analog path. A fastest path to the first verified volume reading is to preserve the verified TDC1000 interface, correct the digital-control and clock faults, bring up one complete ultrasonic measurement path, and use the Sensirion SDP810 backup if it reaches a measured result sooner. My hardware and firmware background also covers sensor integration, calibration routines, OLED output, Bluetooth/serial communication, and editable CAD/enclosure work. I can provide milestone-based work through platform escrow, with the Rev B source files, fabrication package, firmware, test data and hand-off documentation kept organized for your team. Choose me to turn this partly debugged prototype into a measured, testable spirometer platform. Thanks!


Hello, spirometer My 10+ years in electronics and PCB product development cover the full path from schematic and component selection through mixed-signal troubleshooting, ESP32 firmware, prototyping, testing, and manufacturing documentation. That combination fits your Rev B board, end-to-end bring-up, three-unit assembly, and complete hand-off package particularly well. I have practical ESP32, sensor, I2C/UART, embedded-systems, PCB layout, DFM, 3D CAD, and rapid-prototyping experience. For a TDC7200 returning 0xFF, I would first verify power, reset and enable states, SPI mode and timing, chip-select behavior, clock/source configuration, wiring continuity, and whether the device is actually selected, then confirm the waveform at the pins with an oscilloscope. The fastest route to a verified volume reading is to audit and correct the known digital/control faults while exercising the already-verified TDC1000 SPI path, then validate timing and flow math on the bench before expanding the firmware. I can support the milestone-based development and report measured results honestly. Choose me to take this prototype through Rev B hardware, ESP32 integration, testing, CAD integration, and a manufacturing-ready hand-off. Thanks!


Hello, spirometer Over 15 years in electronic hardware and firmware engineering, including medical-device projects, gives me the right foundation to take your ESP32-S3/TDC1000/TDC7200 prototype through Rev B and measured bench testing. I design mixed-signal PCBs in Altium, KiCad and Eagle, and develop ESP32 firmware in C/C++ and Python using SPI, I2C, UART and related interfaces. For a TDC7200 returning 0xFF on every register, I would first verify power, reset and chip-select behavior, SPI mode and clock polarity/phase, MISO electrical activity, grounding, logic levels, and the exact register read sequence against the datasheet. Since your TDC1000 SPI is already verified and the analog chain checked, I would prioritize the known digital faults and fastest path to a real reading rather than redesigning validated circuitry. The fastest route is an initial end-to-end ultrasonic time-of-flight measurement, followed immediately by flow integration and calibration; I would target the first verified volume reading during the early bring-up phase, with exact timing confirmed after file review. My background spans PCB layout, embedded systems, signal processing, and medical and industrial electronics, matching your hardware, firmware, sensor integration, documentation and three-unit handoff requirements. I can deliver the milestone work through platform escrow and provide honest measured results, source files and a complete handoff package Thanks!


Hello, spirometer My background is in architectural, structural, MEP, and civil engineering rather than embedded medical-device development, so I cannot honestly claim prior TDC1000/TDC7200, ESP32 firmware, ultrasonic-flow, or spirometry product experience. My directly listed technical skill is Electrical Engineering, supported by 12+ years coordinating multidisciplinary systems and producing accurate, buildable technical documentation. I can contribute most effectively to the hardware documentation and coordination aspects of this prototype, including reviewing electrical interfaces, organizing revision-controlled deliverables, and preparing clear assembly and hand-off documentation. I am also experienced with SolidWorks, AutoCAD, BIM coordination, and technical drawing packages, which may support enclosure or CAD updates. However, I would not present myself as qualified to independently guarantee the requested firmware, precision-timing diagnosis, flow calibration, or bench-validation milestones. For this project, I recommend selecting a specialist with demonstrated TDC7200/TDC1000, ESP32, mixed-signal PCB, and ultrasonic-flow experience. I would be glad to support that specialist with engineering documentation and coordinated CAD deliverables where needed. Thanks!


spirometer Dear MSTFA Industries Team, Thank you for the detailed project brief. I’m excited by the opportunity to help you bring your handheld spirometer to a functional, bench-tested prototype. My background aligns closely with your needs: I have shipped multiple ultrasonic time-of-flight and flow sensing products, including a high-accuracy water flow meter based on the TDC1000/TDC7200 (±1.5% accuracy over a 0.2–6 L/min range). In that project, I handled full PCB design, firmware (ESP32, both MicroPython and C), and transfer to manufacturing, so I’m comfortable with both rapid prototyping and robust documentation. I also have experience integrating Sensirion pressure sensors and environmental sensors like the BME280, which will streamline your backup and correction paths. I understand you need a fast, practical route to three working units, prioritizing clear measurements over polish at this stage. I’ll begin with a thorough review of your current design and firmware, confirm the hardware fault list, and recommend the fastest reliable route—whether that’s fixing the TI ultrasonic chain or leveraging the Sensirion sensor for v1. My process is milestone-driven, with transparent communication and weekly video check-ins to keep you closely involved. For troubleshooting, I’m well-versed in mixed-signal PCB design (KiCad, Altium), SPI/I2C debug, and bench validation. I have a full lab setup—scopes, logic analyzers, programmable supplies, and calibration syringes—and can receive and assemble hardware in-house (US-based). I look forward to discussing the project and am ready to sign your NDA and IP agreement immediately. Let’s build a spirometer that sets the stage for a successful v2 and beyond. Best regards, Richard


Hi, Dear. I am a licensed electrical engineer with experience in developing and debugging embedded systems, particularly in medical devices. ✅ Expertise in Electrical Engineering, focusing on efficient circuit design and troubleshooting. ✅ Proficient in Rapid Prototyping, ensuring quick iterations and timely delivery. ✅ Skilled in Embedded Systems, with hands-on experience using ESP32 and related components. ✅ Knowledgeable in Signal Processing, facilitating accurate data measurement and analysis. Experience includes successfully developing an ultrasonic flow sensor, achieving high accuracy through precise calibration and testing. Comprehensive documentation and source files will be provided upon project completion. Send me a message to discuss in detail. Thank you.


Hello , I reviewed your project requirements and understand that you're looking for a reliable professional who can deliver high-quality results. I'm an skilled software engineer with expertise in Signal Processing, Firmware Development, Micropython, Electrical Engineering, Embedded Systems, Rapid Prototyping, Product Development and Prototyping. I'm confident I can help you complete this project efficiently while meeting your technical requirements and expectations. My approach is to carefully review your needs, develop a practical solution, and deliver clean, reliable work with clear communication throughout the project. I'd be happy to discuss the details and clarify any technical requirements before getting started. Looking forward to hearing from you. Best regards


Hi there, spirometer prototypes need a fast, evidence-led route to a verified volume reading. I’m an Electronics and Embedded Systems Engineer with 10+ years of embedded development experience, including ESP32, embedded C/C++, and PCB design. I would first audit the known digital faults and verify the TDC7200 interface (SPI mode, CS, reset, clock, power, and wiring), then compare the ultrasonic route with the existing pressure-sensor fallback. A first reading could be targeted within 5-10 days after file and hardware access, subject to the audit. My profile does not document a shipped ultrasonic-flow product, its accuracy, or bench equipment, so I won’t invent those qualifications. I can define milestone scope and pricing after M1 review rather than quote unsupported fixed prices. Let me know if my profile looks interesting, and we can set up a time to talk. Best regards, Vadym P.


spirometer My background in electrical engineering and 15+ years of technical design, documentation, and project coordination enable me to support organized hardware review and engineering deliverables. I can help audit the existing design, document identified faults, coordinate Rev B schematics and PCB files, and prepare a complete manufacturing hand-off package with clear source documentation. I should be transparent that my profile does not document a shipped ultrasonic or flow-sensing product, ESP32/TDC7200 firmware work, measured spirometry accuracy, or access to the requested bench instruments. Therefore, I cannot accurately claim experience with a TDC7200 returning 0xFF or promise the specified end-to-end prototype result. My strongest contribution would be engineering documentation, design review, file organization, CAD coordination, and technical reporting rather than the specialized embedded bring-up required for M2–M4. I would be glad to contribute where my electrical-engineering and documentation experience matches your needs, while recommending that the core assignment go to a specialist with demonstrated TDC1000/TDC7200 and ESP32 prototype experience.


spirometer My background is in electrical engineering, supported by 12+ years delivering coordinated technical design packages for complex construction projects. While my profile does not document prior ESP32, TDC7200, ultrasonic-flow, or medical-device product experience, I can contribute strong engineering documentation, design coordination, and disciplined review practices to the hardware scope. I am experienced in producing accurate, organized technical deliverables and coordinating multidisciplinary work through revisions and final handoff. That is relevant to the Rev B schematic/PCB documentation, BOM and manufacturing package, enclosure coordination, assembly instructions, test procedures, and complete source-file handoff. I would approach this project carefully and report measured prototype performance without overstating accuracy. I would be glad to review the available design files under NDA and determine whether my electrical-engineering experience is the right match for your prototype completion work.


LET'S WORK WITH John! Hello, Greetings , Good evening I am a Professional Engineer with over 10 years of experiencein engineering, building systems design, construction documentation, and multidisciplinary project coordination. Especially, I am skilled in Signal Processing, Product Development, Embedded Systems, Electrical Engineering, Firmware Development, Micropython, Prototyping and Rapid Prototyping. I can provide full set of permit plans. Please send a message to discuss more about this project. Many thanks


⭐⭐⭐⭐⭐ Hi there, Could you confirm the spirometer’s first milestone is to identify the fastest reliable route to a verified volume reading? The priority is diagnosing why the current ultrasonic path has not measured flow, then choosing a dependable Rev B route and validating results honestly. Your clear staged scope makes that decision central. My listed background is in embedded firmware, PCB design, and electronics/robotics. I can’t claim a prior TDC flow product, measured accuracy, or specific bench inventory that isn’t in my profile. ❓ Would you prefer the existing ultrasonic path be tested first, with the SDP810 as a fallback? I’d first check TDC7200 chip-select, reset, SPI mode, and MISO behavior to narrow down the 0xFF reads. I’m ready to review the files and begin with M1. I hope to hear from you and discuss the best next step. Best regards, Nam