U-value and Condensation Risk Calculations
£20-250 GBP
Posted 1 minute ago
•
Ends in 6 days
£20-250 GBP
Paid on delivery
U-value and Condensation Risk Calculations – Apartment Walls, Roofs and Two Skylight Upstands. We are a UK energy assessment consultancy seeking an experienced building physics specialist to undertake U-value calculations and condensation risk assessments for a residential development. The work comprises two separately priced packages: 1. Two timber skylight upstand details Review and assess two timber-framed skylight upstand details, providing U-value calculations, condensation risk assessments and a supporting technical report. Please explain your proposed assessment method and whether it can adequately assess the complete details. If specialist junction modelling or transient hygrothermal analysis is necessary, identify this and price it separately. 2. Apartment wall and roof constructions Review the supplied drawings, identify the distinct wall and roof build-ups, and prepare a construction register with corresponding U-value calculations and condensation risk assessments. Several blocks contain repeated constructions. Identical build-ups should be assessed once, with their application across the blocks clearly recorded. The final number of distinct constructions needs to be established from the drawing review. NHBC requirements The assessments will support an outstanding NHBC condition. The wording supplied by NHBC references BS 5250:2011+A1:2016 and BS EN ISO 13788:2012, with: - Internal temperature: 21°C. - Internal relative humidity: 60% or greater, including winter. - External temperature: −2°C. Reports must identify any predicted condensation, where it occurs, and how it dries out or what mitigation is required. Please identify any limitations of the proposed method or clarification needed regarding these requirements. Deliverables - Register of assessed constructions and drawing revisions. - Calculation reports showing material properties, inputs and assessment conditions. - Clear findings and recommendations suitable for submission to the project team and NHBC. - Editable calculation files alongside PDF reports. - One consolidated round of technical clarification comments. We will provide the available drawings, specifications and NHBC correspondence. Please flag missing information before calculating; assumptions must be agreed with us first. Please include in your proposal - Relevant UK experience, particularly NHBC submissions and timber upstands. - Software and assessment methods proposed. - An anonymised example report. - Separate fees for the two upstands and the apartment constructions, including your rate per additional distinct build-up. - Earliest start date and turnaround time for each package. - Details of professional indemnity insurance. The upstand assessments are the immediate priority. Please do not submit a generic bid without explaining how you would assess these details.
Project ID: 40826834
About the project
5 proposals
Open for bidding
Remote project
Active 12 secs ago
Place your bid
Bid amount Email addressBenefits of bidding on Freelancer
Set your budget and timeframe
It's free to sign up and bid on jobs
5 freelancers are bidding on average £80 GBP for this job


Hello, My architectural engineering and building-regulations background, combined with experience producing UK construction documentation, enables me to review your wall, roof and skylight-upstand details accurately and present them in a clear, submission-ready format. I can work from your drawings and specifications to identify distinct build-ups, record repeated applications across the blocks, and prepare coordinated construction registers, calculation inputs and PDF reports. My BIM and architectural drafting work includes UK house-extension documentation, Revit model QA, detailed construction drawings and revision-tracked technical coordination. I can also provide editable source files alongside the reports and clearly flag missing information or assumptions before assessment. For the timber upstands, I would assess the complete stated details using the supplied construction build-ups and agreed boundary conditions, while clearly identifying any aspect that requires specialist junction modelling or transient hygrothermal analysis rather than presenting an unsupported conclusion. Fees, additional-build-up rates, start date, turnaround and professional indemnity insurance details can be provided as separate package items, together with an anonymised report example where available. I would be pleased to support the immediate upstand priority and the wider NHBC submission. Thanks!


For the two timber skylight upstands I would start with a steady-state U-value check, then an ISO 13788 surface and interstitial condensation check at 21°C, 60% RH and -2°C, and flag any junction that needs a 2D thermal model or transient hygrothermal run before we price it. The apartment build-ups can follow once the drawings are sorted. Do you have the upstand sections with material layers and thicknesses in DWG or PDF? Muhammad


I can review the two timber skylight upstand details and the apartment wall and roof constructions, identify the distinct build-ups from the drawings, and prepare U-value and condensation risk assessments with clear findings for NHBC submission. I will also explain the assessment method for each package, including whether the full details can be covered by BS 5250/BS EN ISO 13788 alone or whether junction modelling or transient hygrothermal analysis is needed. I will use a structured, evidence-based approach with material-property checks, construction registers, drawing revision control, and concise technical reports, plus editable calculation files and PDFs. If any key information is missing, I will flag it before calculating and agree assumptions with you first; I can also share an anonymised example report and confirm availability in UK time. Hira Yousuf


Awesome! The brief clearly separates the priority timber skylight upstands from the apartment wall and roof register. A suitable assessment basis is BS EN ISO 6946 U-value calculation with BS EN ISO 13788 condensation analysis under the stated NHBC conditions; complete upstand performance may additionally require 2D thermal-bridge modelling, while moisture-sensitive timber details may warrant transient hygrothermal analysis. I’d first review the drawings and revisions, identify missing material data, and agree assumptions before calculations begin. The final submission should include traceable inputs, condensation locations, drying or mitigation findings, editable files, PDFs, and an anonymised example report. Separate package fees, the additional-build-up rate, start dates, turnaround, software, relevant UK/NHBC experience, and professional indemnity details would need to be confirmed without unsupported assumptions. Best regards, Robert
内容来自 Freelancer News,版权归原作者所有。
阅读原文 ↗